Skip links

Mild Hyperbaric at 1.3 ATA and Clinical Chambers at 2.0 to 3.0 ATA: The Oxygen Numbers in Kennewick

The mild hyperbaric chamber at Spinal Fitness Health and Wellness Center in Kennewick, WA pressurizes to 1.3 ATA. Clinical hyperbaric oxygen therapy in a hospital runs at 2.0 to 3.0 ATA with 100% oxygen. The Undersea and Hyperbaric Medical Society sets its definition of clinical hyperbaric oxygen therapy at 1.4 ATA or higher while breathing near 100% oxygen. The 2 services differ in 3 numbers: the pressure, the oxygen fraction of the breathing gas, and the oxygen partial pressure those 2 produce together.

Pressure, in 3 units

ATA stands for atmospheres absolute, and 1 ATA is the air pressure at sea level: 760 mmHg, or 14.7 pounds per square inch (psi).

  • 1.0 ATA: 760 mmHg, 14.7 psi. Sea level.
  • 1.3 ATA: 988 mmHg, 19.1 psi. The Kennewick chamber, 4.4 psi above sea level.
  • 1.4 ATA: 1,064 mmHg, 20.6 psi. The lower bound of the clinical definition.
  • 2.0 ATA: 1,520 mmHg, 29.4 psi. A common clinical pressure.
  • 3.0 ATA: 2,280 mmHg, 44.1 psi. The upper clinical range.

A soft-sided chamber holds 1.3 ATA. Pressures of 2.0 ATA and above are delivered in rigid chambers.

Oxygen partial pressure: Dalton’s law

Dalton’s law states that each gas in a mixture exerts a partial pressure equal to its fraction of the mixture times the total pressure. Air is about 21% oxygen. Oxygen partial pressure is the figure the lungs and the blood respond to, and it is the product of the 2 numbers.

  • Room air at 1.0 ATA: 0.21 atmospheres of oxygen, 160 mmHg.
  • Room air at 1.3 ATA: 0.27 atmospheres of oxygen, 207 mmHg. That is 1.3 times sea level.
  • 100% oxygen at 2.0 ATA: 2.0 atmospheres of oxygen, 1,520 mmHg. That is 9.5 times sea-level room air.
  • 100% oxygen at 3.0 ATA: 3.0 atmospheres of oxygen, 2,280 mmHg. That is 14.3 times sea-level room air.

In the Kennewick chamber an oxygen concentrator supplies enriched air through a nasal cannula. The cannula raises the oxygen fraction of each breath above 21%, and the 1.3 ATA pressure multiplies that higher fraction by 1.3. The inspired oxygen partial pressure in a session is therefore above the 207 mmHg room-air figure and below the clinical figures.

Dissolved oxygen: Henry’s law

Most oxygen in blood travels bound to hemoglobin, which is already about 97% saturated when breathing room air at sea level. A smaller share travels dissolved in the plasma, and Henry’s law sets that share: the amount of a gas dissolved in a liquid is directly proportional to the partial pressure of that gas above the liquid. Raising the oxygen partial pressure 1.3 times raises the dissolved oxygen 1.3 times. Hemoglobin has little room to carry more, so the dissolved share in plasma is where a pressure increase adds oxygen.

1.3 ATA and 2.0 ATA as multiples of sea level

Eileen Durfee, who founded the center, states the position this way: mild pressure has benefits of its own, and the pressure is lower than the 3 ATA used in clinical chambers. A 1.3 ATA session is a calculable 30% rise in ambient pressure and at least a 30% rise in oxygen partial pressure. A clinical session at 2.0 ATA on 100% oxygen is a 9.5-fold rise. The center’s service page separates the 2: clinical hyperbaric oxygen therapy is a medical service delivered at higher pressures in hospital settings under physician supervision for specific medical indications, and the center’s sessions are a wellness service in a soft-sided chamber at a mild 1.3 ATA.

How the 2 sessions compare

  • Pressure: 1.3 ATA in Kennewick; 2.0 to 3.0 ATA in a clinical chamber.
  • Breathing gas: concentrator-enriched air by nasal cannula; 100% oxygen by hood, mask or an oxygen-filled chamber.
  • Chamber: soft-sided; rigid.
  • Supervision: self-directed after training is complete; physician-supervised.
  • Purpose: a wellness service; a medical service for specific indications.
  • Session in Kennewick: a booked session is 90 minutes and a member session is 1 hour, lying on a grounded mat, fully clothed in cotton, shoes off, 0 electronics inside.

Ears and screening at 1.3 ATA

Boyle’s law applies at any pressure above 1.0 ATA. At 1.3 ATA a trapped air space shrinks to about 77% of its sea-level volume, and the middle ear registers that change, so ear-equalization techniques are reviewed at orientation. Every guest completes a health questionnaire before a first 1.3 ATA session. Pregnancy, certain lung or ear conditions, recent ear surgery and an implanted medical device call for clearance from a healthcare provider before a session. You can depressurize the chamber from 1.3 ATA and exit at any time.

Booking in Kennewick

A booked session is 90 minutes for $100, 6 sessions are $525, and Hyperbaric Unlimited Monthly is $700 for 1 session per calendar day. Membership sessions run 1 hour: the $150 Month-to-Month membership includes 1 a month. Hyperbaric sessions are always booked, and members who have completed their training run their own sessions with 24/7 door-code access. Every Thursday from 2:00 to 6:00 PM the center offers new visitors 1 free session of a rotating service: BioCharger NG, the 7 Wave light panel, Brown’s Gas, PEMF or the hot exercise room. Spinal Fitness Health and Wellness Center is at 214 E. Albany Ave, Building E101, Kennewick, WA 99336, serving Kennewick, Pasco, Richland, West Richland, Benton City and Walla Walla. Call or text 509-670-9713.